一.
Pre operation examination items
should be in accordance with the following requirements:
A.
All parts of the structure
without deformation, connecting bolts loose;
B.
The rack and pinion, the guide
wheel and the wheel / rail joint are normal;
C.
All the wire ropes are fixed,
no abnormal wear;
D.
No obstacles in operation;
二.
Before starting, check and make
sure that the cable is in the zero position. After power is turned on, should
check and confirm the voltage is normal, should test no leakage phenomenon.
Should test and confirm the limiting device, cage ladder, enclosure door, etc.
the interlock device is good and reliable, electric appliances, instruments and
meters, sensitive and effective, after the start should be no-load lifting test,
determination of the transmission brake efficiency, confirm normal rear can
start work.
三.
The operator should according
to the command signal operation, before operation of. Before the lift off the
power switch, the operator may not leave the operation.
四.
When the building hoist is found to have
abnormal conditions, should immediately stop and take effective measures to
lower the ladder cage to the end, to remove the fault can continue to run. When
the electrical control is found in the operation, press the emergency stop
button immediately.
五.
Lift in heavy rain, fog, six
and above the wind and rail, cable and other ice, we must stop running, and the
ladder cage down to the end, cut off power. After the storm, the safety device
of the elevator should be checked, and the group can run.
六.
When the lift is running to the
upper or lower level, it is forbidden to use the travel limit switch as the
control switch to stop running.
七.
When the lift in operation due
to the power or other reasons and stop, down by hand, the motor is arranged at
the tail end of the braking electromagnet manual release handle slowly out, the
ladder cage slowly downward slide. When the ladder is in decline, it is not
allowed to exceed the rated operating speed, and manual drop must be operated
by professional maintenance personnel.
八.
After the operation, the ladder
should be reduced to the end of the floor, the control switch to zero, cut off
power, the lock good switch box, closed ladder cage door and door.